Waste water heat recuperation in the hotel
Waste water heat recuperation in the hotel
The calculation is made on the basis of a consolidated analysis of the audit reports of specialized companies. The calculation takes into account the peak loads for the hotel of the tourist destination.
General information about the object *:
Location | Spain |
Number of rooms | 150 |
Number of people staying in the room | 2 |
Average hotel occupancy by year | 75% |
Number of hotel stars | 4 |
Technical information about the object *:
Hot water consumption per person | 80 l |
The ratio of hot water to cold | 40/60 |
Cold water temperature | 10 С |
Temperature at the outlet of the boiler room | 60 С |
Wastewater temperature | 25 С |
Type of heat source | Natural gas |
The cost of energy | 53 EUR **** |
Boiler room efficiency | 90%** |
Estimated information on annual consumption:
Volume of hot water consumption | 6 132 m3 |
Volume of wastewater per year | 15 330 m3 |
Total amount of energy for heating | 396,12 MW*h |
Current water heating costs | 20 994 EUR |
Calculation of the efficiency of the installation of the recuperation system:
Type of system | passive |
Type of connection to the DHW system | Plate heat exchanger |
Recuperation power | 36,11 kW |
Total annual recuperation | 106,95 MW*h |
Savings from implementation | 5 668 EUR |
The cost of the system | 22 000 EUR*** |
ROI | 3,88 years |
* The calculation is based on a summary analysis of the audit reports of specialized companies. The calculation takes into account peak loads for a tourist destination hotel.
** The weighted average value for typical equipment on the market is accepted
*** The value from the experience of previous installations of similar systems is accepted
**** All financial indicators are reflected without VAT
-
The cost of the system
22000 EUR
-
ROI
3.88 years
-
SAVINGS FROM IMPLEMENTATION:
5668 EUR
-
TOTAL ANNUAL RECUPERATION:
106,95 MW*h/year
-
RECUPERATION POWER:
kW